Bedeutung

Sensor aus Abgasanlage entfernt

Ursachen & Abhilfe

Ursache: O2 value measured at one of the two Nox sensors (upstream SCR) is above 19 % when injected fuel quantity is above 110 mg/str for more than 30 s.
Pruefung:
Abhilfe: