BiG M 450 - Fehler LMB-ECU2-1239-2 Excel Export (CSV)

Ursachen & Abhilfe

Ursache: At the transition from engine running to engine stopped, a timer is started. Once the timer reaches 0.800 s the pressure value is stored and after a second delay of 2.300 s the current common rail pressure is compared with the previously stored value. This difference of both values is greater than the calibrated curve FuDiagPHi1_RpmLeakAtDly1_MAP (depending on engine speed and common rail pressure (both measured after first delay (0.800 s)).
Pruefung:
Abhilfe: Falls erkannt mit dem Fehler "Common Rail - Plausiblitätsfehler des Vcv Stroms" und / oder "Common Rail - Druck bleibt unter Sollwert", prüfen Sie die Hochdruckpumpe. Andernfalls ist keine Aktion erforderlich